National Hotline Service

:13688942146

News Center

News Center

You Are Here : Home > News > Air conditioning > Central air-conditioning purification device: why should the central air-conditioning system be equipped with an air purification device

Central air-conditioning purification device: why should the central air-conditioning system be equipped with an air purification device

2022-08-18 00:00:00

Central air-conditioning purification device: why should the central air-conditioning system be equipped with an air purification device

Article 2 These measures are applicable to the sanitation management of centralized air-conditioning and ventilation systems in public places. The centralized air-conditioning and ventilation systems in other places shall be implemented with reference to this method.

Article 3 The centralized air-conditioning and ventilation system in public places (hereinafter referred to as the central air-conditioning and ventilation system) shall meet the requirements of the "Sanitary Specifications for Centralized Air-conditioning and Ventilation Systems in Public Places" and the requirements of relevant sanitation standards.

The operator of a public place shall take measures to ensure that the centralized air-conditioning and ventilation system of the place meets the requirements of the preceding paragraph.

Article 6 The centralized air-conditioning and ventilation system shall have the following facilities:

(1) Devices for emergency shutdown of return air and fresh air;

(2) Devices for controlling the sub-regional operation of the air-conditioning system;

(3) Air purification and disinfection devices;

(4) Openable and closable windows for cleaning and disinfection of the air duct system.

Article 7 The newly built, reconstructed and expanded central air conditioning and ventilation systems shall undergo hygienic evaluation for the prevention of airborne diseases, and can be put into operation only after the evaluation is passed.

The central air-conditioning and ventilation system that has been put into operation shall undergo a hygienic evaluation for the prevention of airborne diseases every two years, and can continue to operate after the evaluation is passed.

The hygienic evaluation shall comply with the provisions of the "Specifications for Hygienic Evaluation of Central Air Conditioning and Ventilation Systems in Public Places".

Article 19 The meanings of the terms in these Measures are as follows:

Centralized air conditioning and ventilation system: In order to make the parameters of room or closed space air temperature, humidity, cleanliness and airflow speed meet the set requirements, all equipment, pipes and accessories, instruments and meters for centralized processing, transportation and distribution of air are provided. sum.

Air duct system: air ducts, air outlets, air handling units and other parts used to process and transport air in the central air conditioning ventilation system.

Airborne diseases: diseases that are mainly transmitted through the air.


Central air conditioning purification device

Url of this article : http://en.v-1.com.cn/news/27.html

Related Products

Related News

尾部logo

V1 Environmental Technology Co,. Ltd 

 Contact: Manager Xie 

 Phone: 13688942146 

 Switchboard: 0769-81667033 

 Email :james@v-1.com.cn 

 Address: No.5, Jiangbei Xinkang Road, Wusha Village, Changan Town, Dongguan City

 ICP: Guangdong ICP Bei 15026159

V1